Puma 761 & 762 Specs
- GENERAL
- Configuration
- Up to 6 degrees of motion
- Drive
- Controller
- System Computer (LSI-11), with CRT
- Teaching Method
- By teach control and/or computer terminal
- Program Language
- Program Capacity
- 24KW CMOS user memory in VAL II
- External Program Storage
- I/O Module
- 32 input/32 output AC/DC user selectable voltage range, plus control
I/O's
- Gripper Control
- Power Requirement
- 240-380/415/480 Volts, 3-phase, 4500 watts (peak)
- ENVIRONMENTAL OPERATING RANGE
- 50-120°F (10-50°C)
- 95% relative humidity (non-condensing)
- Shielded against momentary industrial line fluctuations of -15%,
+200% of nominal voltage and up to 10KV electrostatic discharge. All covers
and rotary seals have gaskets to protect against water spray and dust.
Designed to comply with IP54 and NEMA 12 International Electrical Packaging
Specifications.
- PHYSICAL CHARACTERISTICS
Model 761 Model 762 -------------------------------------------
Arm Weight 1276 lbs (580 kg) 1298 lbs (590 kg) Base Diameter 23.6 in. (0.6m)
23.6 in. (0.6m) Control Cabinet Size (both) 45.6 in.H x 23.6 in.W x 31.5
in.D (1160mm x 600mm x 800mm) Weight 440 lbs. (200kg)
- Performance
Model 761 Model 762
---------------------------------------------------
Repeatability (both) +/- 0.008 in. (0.2mm)
Maximum Payload
Static Load 22 lbs. (10 kg) 44 lbs (20 kg)
Dynamic Load Around Joint 5 1365 lb.-in² (4000 kg-in²) 4270 lb.-in² (12500
10 kg load concentrated kg-cm²) 20 kg load
20 cm from JT5 (tool flange concentrated 25cm from JT5
is 12.5 cm from JT5) (tool flange is 12.5cm from JT5)
Dynamic Load Around Joint 6 340 lb.-in² (1000 kg-cm²) 683 lb.-in² (2000 kg-cm²)
10 kg concentrated at 10 cm 20 kg concentrated at 10 cm
from JT6 from JT6
Straight Line Velocity (both) 40 in./sec. (1.0m/sec) max.
Puma Home
|